Now the function properly uses ring arithmetic to return signed value
in range (inclusive):
[-MICROPY_PY_UTIME_TICKS_PERIOD/2, MICROPY_PY_UTIME_TICKS_PERIOD/2-1].
That means that function can properly process 2 time values away from
each other within MICROPY_PY_UTIME_TICKS_PERIOD/2 ticks, but away in
both directions. For example, if tick value 'a' predates tick value 'b',
ticks_diff(a, b) will return negative value, and positive value otherwise.
But at positive value of MICROPY_PY_UTIME_TICKS_PERIOD/2-1, the result
of the function will wrap around to negative -MICROPY_PY_UTIME_TICKS_PERIOD/2,
in other words, if a follows b in more than MICROPY_PY_UTIME_TICKS_PERIOD/2 - 1
ticks, the function will "consider" a to actually predate b.
Based on the earlier discussed RFC. Practice showed that the most natural
order for arguments corresponds to mathematical subtraction:
ticks_diff(x, y) <=> x - y
Also, practice showed that in real life, it's hard to order events by time
of occurance a priori, events tend to miss deadlines, etc. and the expected
order breaks. And then there's a need to detect such cases. And ticks_diff
can be used exactly for this purpose, if it returns a signed, instead of
unsigned, value. E.g. if x is scheduled time for event, and y is the current
time, then if ticks_diff(x, y) < 0 then event has missed a deadline (and e.g.
needs to executed ASAP or skipped). Returning in this case a large unsigned
number (like ticks_diff behaved previously) doesn't make sense, and such
"large unsigned number" can't be reliably detected per our definition of
ticks_* function (we don't expose to user level maximum value, it can be
anything, relatively small or relatively large).
In order to have more fine-grained control over how builtin functions are
constructed, the MP_DECLARE_CONST_FUN_OBJ macros are made more specific,
with suffix of _0, _1, _2, _3, _VAR, _VAR_BETEEN or _KW. These names now
match the MP_DEFINE_CONST_FUN_OBJ macros.
As long as a port implement mp_hal_sleep_ms(), mp_hal_ticks_ms(), etc.
functions, it can just use standard implementations of utime.sleel_ms(),
utime.ticks_ms(), etc. Python-level functions.
This refactors ujson.loads(s) to behave as ujson.load(StringIO(s)).
Increase in code size is: 366 bytes for unix x86-64, 180 bytes for
stmhal, 84 bytes for esp8266.
As per discussion in #2449, using write requests instead of read requests
for I2C.scan() seems to support a larger number of devices, especially
ones that are write-only. Even a read-only I2C device has to implement
writes in order to be able to receive the address of the register to read.
Adds check that LZ offsets fall into the sliding dictionary used. This
catches a case when uzlib.DecompIO with a smaller dictionary is used
to decompress data which was compressed with a larger dictionary.
Previously, this would lead to producing invalid data or crash, now
an exception will be thrown.
The delay_half parameter must be specified by the port to set up the
timing of the software SPI. This allows the port to adjust the timing
value to better suit its timing characteristics, as well as provide a
more accurate printing of the baudrate.
There is no need to take src_len and dest_len arguments. The case of
reading-only with a single output byte (originally src_len=1, dest_len>1)
is now handled by using the output buffer as the input buffer, and using
memset to fill the output byte into this buffer. This simplifies the
implementations of the spi_transfer protocol function.
The memory read/write I2C functions now take an optional keyword-only
parameter that specifies the number of bits in the memory address.
Only mem-addrs that are a multiple of 8-bits are supported (otherwise
the behaviour is undefined).
Due to the integer type used for the address, for values larger than 32
bits, only 32 bits of address will be sent, and the rest will be padded
with 0s. Right now no exception is raised when that happens. For values
smaller than 8, no address is sent. Also no exception then.
Tested with a VL6180 sensor, which has 16-bit register addresses.
Due to code refactoring, this patch reduces stmhal and esp8266 builds
by about 50 bytes.
When the clock is too fast for the i2c slave, it can temporarily hold
down the scl line to signal to the master that it needs to wait. The
master should check the scl line when it is releasing it after
transmitting data, and wait for it to be released.
This change has been tested with a logic analyzer and an i2c slace
implemented on an atmega328p using its twi peripheral, clocked at 8Mhz.
Without the change, the i2c communication works up to aboy 150kHz
frequency, and above that results in the slave stuck in an unresponsive
state. With this change, communication has been tested to work up to
400kHz.
Adds horizontal scrolling. Right now, I'm just leaving the margins
created by the scrolling as they were -- so they will repeat the
edge of the framebuf. This is fast, and the user can always fill
the margins themselves.
There was a bug in `framebuf1_fill` function, that makes it leave a few
lines unfilled at the bottom if the height is not divisible by 8.
A similar bug is fixed in the scroll method.
The idea is that all ports can use these helper methods and only need to
provide initialisation of the SPI bus, as well as a single transfer
function. The coding pattern follows the stream protocol and helper
methods.
This is an object-oriented approach, where uos is only a proxy for the
methods on the vfs object. Some internals had to be exposed (the STATIC
keyword removed) for this to work.
Fixes#2338.
In `btree_seq()`, when `__bt_seq()` gets called with invalid
`flags` argument it will return `RET_ERROR` and it won't
initialize `val`. If field `data` of uninitialized `val`
is passed to `mp_obj_new_bytes()` it causes a segfault.
This goes bit against websocket nature (message-based communication),
as it ignores boundaries bertween messages, but may be very practical
to do simple things with websockets.
In the sense that while GET_FILE transfers its data, REPL still works.
This is done by requiring client to send 1-byte block before WebREPL
server transfers next block of data.
Storing a chain of pbuf was an original design of @pfalcon's lwIP socket
module. The problem with storing just one, like modlwip does is that
"peer closed connection" notification is completely asynchronous and out of
band. So, there may be following sequence of actions:
1. pbuf #1 arrives, and stored in a socket.
2. pbuf #2 arrives, and rejected, which causes lwIP to put it into a
queue to re-deliver later.
3. "Peer closed connection" is signaled, and socket is set at such status.
4. pbuf #1 is processed.
5. There's no stored pbufs in teh socket, and socket status is "peer closed
connection", so EOF is returned to a client.
6. pbuf #2 gets redelivered.
Apparently, there's no easy workaround for this, except to queue all
incoming pbufs in a socket. This may lead to increased memory pressure,
as number of pending packets would be regulated only by TCP/IP flow
control, whereas with previous setup lwIP had a global overlook of number
packets waiting for redelivery and could regulate them centrally.
Allows to translate C-level pin API to Python-level pin API. In other
words, allows to implement a pin class and Python which will be usable
for efficient C-coded algorithms, like bitbanging SPI/I2C, time_pulse,
etc.
The time stamp is taken from the RTC for all newly generated
or changed files. RTC must be maintained separately.
The dummy time stamp of Jan 1, 2000 is set in vfs.stat() for the
root directory, avoiding invalid time values.
The call to stat() returns a 10 element tuple consistent to the os.stat()
call. At the moment, the only relevant information returned are file
type and file size.
Using usual method of virtual method tables. Single virtual method,
ioctl, is defined currently for all operations. This universal and
extensible vtable-based method is also defined as a default MPHAL
GPIO implementation, but a specific port may override it with its
own implementation (e.g. close-ended, but very efficient, e.g. avoiding
virtual method dispatch).
Make dupterm subsystem close a term stream object when EOF or error occurs.
There's no other party than dupterm itself in a better position to do this,
and this is required to properly reclaim stream resources, especially if
multiple dupterm sessions may be established (e.g. as networking
connections).
Both read and write operations support variants where either a) a single
call is made to the undelying stream implementation and returned buffer
length may be less than requested, or b) calls are repeated until requested
amount of data is collected, shorter amount is returned only in case of
EOF or error.
These operations are available from the level of C support functions to be
used by other C modules to implementations of Python methods to be used in
user-facing objects.
The rationale of these changes is to allow to write concise and robust
code to work with *blocking* streams of types prone to short reads, like
serial interfaces and sockets. Particular object types may select "exact"
vs "once" types of methods depending on their needs. E.g., for sockets,
revc() and send() methods continue to be "once", while read() and write()
thus converted to "exactly" versions.
These changes don't affect non-blocking handling, e.g. trying "exact"
method on the non-blocking socket will return as much data as available
without blocking. No data available is continued to be signaled as None
return value to read() and write().
From the point of view of CPython compatibility, this model is a cross
between its io.RawIOBase and io.BufferedIOBase abstract classes. For
blocking streams, it works as io.BufferedIOBase model (guaranteeing
lack of short reads/writes), while for non-blocking - as io.RawIOBase,
returning None in case of lack of data (instead of raising expensive
exception, as required by io.BufferedIOBase). Such a cross-behavior
should be optimal for MicroPython needs.
Calling it from lwIP accept callback will lead incorrect functioning
and/or packet leaks if Python callback has any networking calls, due
to lwIP non-reentrancy. So, instead schedule "poll" callback to do
that, which will be called by lwIP when it does not perform networking
activities. "Poll" callback is called infrequently though (docs say
every 0.5s by default), so for better performance, lwIP needs to be
patched to call poll callback soon after accept callback, but when
current packet is already processed.
While just a websocket is enough for handling terminal part of WebREPL,
handling file transfer operations requires demultiplexing and acting
upon, which is encapsulated in _webrepl class provided by this module,
which wraps a websocket object.
To use: .setsockopt(SOL_SOCKET, 20, lambda sock: print(sock)). There's a
single underlying callback slot. For normal sockets, it serves as data
received callback, for listening sockets - connection arrived callback.
The idea is that if dupterm object can handle exceptions, it will handle
them itself. Otherwise, object state can be compromised and it's better
to terminate dupterm session. For example, disconnected socket will keep
throwing exceptions and dump messages about that.
When lwIP creates a incoming connection socket of a listen socket, it