When MICROPY_SCHEDULER_STATIC_NODES is enabled, the logic is unchanged.
When MICROPY_SCHEDULER_STATIC_NODES is disable, sched_state is now always
initialised to MP_SCHED_IDLE when calling mp_init(). For example, the use
of mp_sched_vm_abort(), if it aborts a running scheduled function, can lead
to the scheduler starting off in a locked state when the runtime is
restarted, and then it stays locked. This commit fixes that case by
resetting sched_state.
Signed-off-by: Damien George <damien@micropython.org>
Previously sys.path could be modified by append/pop or slice assignment.
This allows `sys.path = [...]`, which can be simpler in many cases, but
also improves CPython compatibility.
It also allows sys.path to be set to a tuple which means that you can
clear sys.path (e.g. temporarily) with no allocations.
This also makes sys.path (and sys.argv for consistency) able to be disabled
via mpconfig. The unix port (and upytesthelper) require them, so they
explicitly verify that they're enabled.
This work was funded through GitHub Sponsors.
Signed-off-by: Jim Mussared <jim.mussared@gmail.com>
This reduces the stack frame size of mp_builtin___import__ by
limiting the support path length of files from 256 to 96. This
function can be called recursively for nested imports so it adds up.
Also reduce mp_execute_bytecode (vm.c) from 206 a bc call to 124.
This too is recursive and adds up. It is reduced by preventing
some inlining. It may decrease performance slightly when importing
and unpacking.
Adds two new scripts for debugging. One is used from gdb to print
frame sizes in a backtrace. The other prints what pcs use a
particular stack offset. This helps find infrequently used stack
space.
Fixes#8053.
The changed functions now use less stack, and don't have any issues with
local variables needing to be declared volatile.
Testing on a PYBv1.0, imports (of .py, .mpy and frozen code) now use 64
less bytes of C stack per import depth.
Signed-off-by: Damien George <damien@micropython.org>
This makes it so that sub-packages are resolved relative to their parent's
`__path__`, rather than re-resolving each parent's filesystem path.
The previous behavior was that `import foo.bar` would first re-search
`sys.path` for `foo`, then use the resulting path to find `bar`.
For already-loaded and u-prefixed modules, because we no longer need to
build the path from level to level, we no longer unnecessarily search
the filesystem. This should improve startup time.
Explicitly makes the resolving process clear:
- Loaded modules are returned immediately without touching the filesystem.
- Exact-match of builtins are also returned immediately.
- Then the filesystem search happens.
- If that fails, then the weak-link handling is applied.
This maintains the existing behavior: if a user writes `import time` they
will get time.py if it exits, otherwise the built-in utime. Whereas `import
utime` will always return the built-in.
This also fixes a regression from a7fa18c203
where we search the filesystem for built-ins. It is now only possible to
override u-prefixed builtins. This will remove a lot of filesystem stats
at startup, as micropython-specific modules (e.g. `pyb`) will no longer
attempt to look at the filesystem.
Added several improvements to the comments and some minor renaming and
refactoring to make it clearer how the import mechanism works. Overall
code size diff is +56 bytes on STM32.
This work was funded through GitHub Sponsors.
Signed-off-by: Jim Mussared <jim.mussared@gmail.com>
To be consistent with MP_UNARY_OP_INT_FLOAT and MP_UNARY_OP_INT_COMPLEX,
and allow int() to first check if a type supports __int__ before trying
other things (as per CPython).
Signed-off-by: Damien George <damien@micropython.org>
The code that handles inplace-operator to normal-binary-operator fallback
is moved in this commit from py/objtype.c to py/runtime.c, making it apply
to all types, not just user classes.
Signed-off-by: Damien George <damien@micropython.org>
Since converting to variable sized slots in mp_obj_type_t, we can now
reduce the code size a bit by removing mp_generic_unary_op() and the
corresponding slots where it is used. Instead we just implement the
generic `__hash__` operation in the runtime.
Signed-off-by: David Lechner <david@pybricks.com>
* Enable dcache for OCRAM where the VM heap lives.
* Add CIRCUITPY_SWO_TRACE for pushing program counters out over the
SWO pin via the ITM module in the CPU. Exempt some functions from
instrumentation to reduce traffic and allow inlining.
* Place more functions in ITCM to handle errors using code in RAM-only
and speed up CP.
* Use SET and CLEAR registers for digitalio. The SDK does read, mask
and write.
* Switch to 2MiB reserved for CircuitPython code. Up from 1MiB.
* Run USB interrupts during flash erase and write.
* Allow storage writes from CP if the USB drive is disabled.
* Get perf bench tests running on CircuitPython and increase timeouts
so it works when instrumentation is active.
If an exception's chain or context can refer to a pointer from a different
VM, a crash would typically result.
This couldn't turn up on UNIX testing because the VM is never torn
down and rebuilt like it is on hardware.
Because in the 'static' case the GeneratorObject is now fully initialized
whenever it's raised, the initialization can be dropped, which reduces
the flash size slightly.
Closes: #7565
Instead of being an explicit field, it's now a slot like all the other
methods.
This is a marginal code size improvement because most types have a make_new
(100/138 on PYBV11), however it improves consistency in how types are
declared, removing the special case for make_new.
Signed-off-by: Jim Mussared <jim.mussared@gmail.com>
The goal here is to remove a slot (making way to turn make_new into a slot)
as well as reduce code size by the ~40 references to mp_identity_getiter
and mp_stream_unbuffered_iter.
This introduces two new type flags:
- MP_TYPE_FLAG_ITER_IS_ITERNEXT: This means that the "iter" slot in the
type is "iternext", and should use the identity getiter.
- MP_TYPE_FLAG_ITER_IS_CUSTOM: This means that the "iter" slot is a pointer
to a mp_getiter_iternext_custom_t instance, which then defines both
getiter and iternext.
And a third flag that is the OR of both, MP_TYPE_FLAG_ITER_IS_STREAM: This
means that the type should use the identity getiter, and
mp_stream_unbuffered_iter as iternext.
Finally, MP_TYPE_FLAG_ITER_IS_GETITER is defined as a no-op flag to give
the default case where "iter" is "getiter".
Signed-off-by: Jim Mussared <jim.mussared@gmail.com>
The reallocation trigger for unpacking star args with unknown length
did not take into account the number of fixed args remaining. So it was
possible that the unpacked iterators could take up exactly the memory
allocated then nothing would be left for fixed args after the star args.
This causes a segfault crash.
This is fixed by taking into account the remaining number of fixed args
in the check to decide whether to realloc yet or not.
Signed-off-by: David Lechner <david@pybricks.com>
It's no longer needed because this macro is now processed after
preprocessing the source code via cpp (in the qstr extraction stage), which
means unused MP_REGISTER_MODULE's are filtered out by the preprocessor.
Signed-off-by: Damien George <damien@micropython.org>
.. and enable it on atmel-samd and raspberrypi. On trinket_m0 this saves
96 net bytes of flash. There are 216 bytes actually saved by reducing
the flash storage size of the property descriptors, but added code in
several paths takes back over half of the 'raw savings'.
By organizing the "get-only" and "get-set" (but no delete) properties
each in a different section, we can represent then more efficiently.
Testing performed: that a get-only property can still be gotten but
can't be set or deleted; that a get-set property can sill be gotten or
set but can't be deleted. Tested on pygamer.
Because this requires linker file support, I only enabled it on two of
the ports.
This replaces occurences of
foo_t *foo = m_new_obj(foo_t);
foo->base.type = &foo_type;
with
foo_t *foo = mp_obj_malloc(foo_t, &foo_type);
Excludes any places where base is a sub-field or when new0/memset is used.
Signed-off-by: Jim Mussared <jim.mussared@gmail.com>
If MICROPY_SCHEDULER_STATIC_NODES is enabled then C code can declare a
static mp_sched_node_t and schedule a callback using
mp_sched_schedule_node(). In contrast to using mp_sched_schedule(), the
node version will have at most one pending callback outstanding, and will
always be able to schedule if there is nothing already scheduled on this
node. This guarantees that the the callback will be called exactly once
after it is scheduled.
Signed-off-by: Damien George <damien@micropython.org>
The values are always real objects, only the key can be MP_OBJ_NULL to
indicate a **kwargs entry.
Signed-off-by: Damien George <damien@micropython.org>
There were two issues with the existing code:
1. "1 << i" is computed as a 32-bit number so would overflow when
executed on 64-bit machines (when mp_uint_t is 64-bit). This meant that
*args beyond 32 positions would not be handled correctly.
2. star_args must fit as a positive small int so that it is encoded
correctly in the emitted code. MP_SMALL_INT_BITS is too big because it
overflows a small int by 1 bit. MP_SMALL_INT_BITS - 1 does not work
because it produces a signed small int which is then sign extended when
extracted (even by mp_obj_get_int_truncated), and this sign extension
means that any position arg after *args is also treated as a star-arg.
So the maximum bit position is MP_SMALL_INT_BITS - 2. This means that
MP_OBJ_SMALL_INT_VALUE() can be used instead of
mp_obj_get_int_truncated() to get the value of star_args.
These issues are fixed by this commit, and a test added.
Signed-off-by: Damien George <damien@micropython.org>
This replaces instances of uint with size_t and int with ssize_t in
the mp_call_prepare_args_n_kw_var() function since all of the variables
are used as array offsets.
Also sort headers while we are touching this.
Signed-off-by: David Lechner <david@pybricks.com>
To reach this check, n_kw has to be >= 1 and therefore args2_alloc has
to be >= 2. Therefore new_alloc will always be >= 4. So this check will
never be true and can be removed.
Signed-off-by: David Lechner <david@pybricks.com>