Commit Graph

14622 Commits

Author SHA1 Message Date
Damien George
d65edaa232 webassembly: Use Date's now() instead of getTime().
Using now() is a bit faster because it doesn't need to create a new Date.

Signed-off-by: Damien George <damien@micropython.org>
2022-11-03 18:47:48 +11:00
Damien George
49ce93eeec github/workflows: Print test failures for webassembly workflow.
Signed-off-by: Damien George <damien@micropython.org>
2022-11-03 18:47:48 +11:00
Damien George
329f8252b9 tests/run-perfbench: Support --heapsize argument and pass to executable.
Signed-off-by: Damien George <damien@micropython.org>
2022-11-03 17:33:25 +11:00
Damien George
b52fe52d31 tools/makemanifest.py: Fix printing of mpy_cross.CrossCompileError.
This change was missed by 5852fd7708

Signed-off-by: Damien George <damien@micropython.org>
2022-11-02 14:06:18 +11:00
Damien George
46bb52adf6 webassembly: Add support for VFS and enable VFS_POSIX.
This gets filesystem support working.

Signed-off-by: Damien George <damien@micropython.org>
2022-11-01 13:53:06 +11:00
Damien George
54478eb9e7 webassembly/mpconfigport: Use MICROPY_CONFIG_ROM_LEVEL_EXTRA_FEATURES.
This simplifies the config file.  This is not a no-op, it does enable a few
new features to bring the port in line with this config level.

Signed-off-by: Damien George <damien@micropython.org>
2022-11-01 13:10:45 +11:00
Damien George
da36b84d45 extmod/vfs_posix: Include errno.h and unistd.h headers.
errno.h is needed for the errno variable, and unistd.h is needed for chdir.

Signed-off-by: Damien George <damien@micropython.org>
2022-11-01 13:10:45 +11:00
Damien George
3ed017677b tools/mpremote: Make RemoteFile objects iterable.
So that filesystems mounted with "mpremote mount" can have their files
iterated over, making them consistent with other files.

Signed-off-by: Damien George <damien@micropython.org>
2022-10-31 12:40:17 +11:00
Jim Mussared
3427e12e8f tools/mpremote: Handle FileNotFound exceptions in listdir.
The except handler for OSError didn't include the line that actually calls
os.listdir, so an invalid path wasn't handled correctly.

Signed-off-by: Jim Mussared <jim.mussared@gmail.com>
2022-10-31 12:38:25 +11:00
robert-hh
7775523b2d esp32/machine_pwm: Verify PWM is active when config methods are called.
Checks are added for pwm.freq(), pwm_duty(), pwm_duty_u10() and
pwm.duty_u16().  This avoids a core dump on ESP32C3, and misleading error
messages on Xtensa ESP32 devices.
2022-10-31 11:54:46 +11:00
Ihor Nehrutsa
5b2929a0e6 esp32/machine_pin: Fix size of machine_pin_irq_handler array.
Set the size of machine_pin_irq_handler array to GPIO_NUM_MAX:
- Min GPIO_NUM_MAX is 22 for IDF_TARGET_ESP32C3.
- Max GPIO_NUM_MAX is 49 for IDF_TARGET_ESP32S3.

The MP_REGISTER_ROOT_POINTER entry must be hard-coded, because the location
that it's evaluated by the compiler does not include the relevant IDF
header to get a definition of GPIO_NUM_MAX.
2022-10-31 11:42:20 +11:00
Mark Grosen
12f9948151 esp32/machine_i2c: Fix clocks and timeouts for ESP32-C3, ESP32-S3.
Each SoC family has its own clocks and timings/timeouts. For I2C, the
default source clock is either APB (ESP32, ESP32-S2) or XTAL (ESP32-S3,
ESP32-C3) as shown in the datasheets.  Since
machine_i2c.c/machine_hw_i2c_init() uses the default clk_flags (0), the
alternate low-power clock source is never selected in ESP-IDF
i2c.c/i2c_param_config().  There is not an API in i2c.c to get the source
clock frequency, so a compile-time value is used based on SoC family.

Also, the maximum timeout is different across the SoC families, so use the
I2C_LL_MAX_TIMEOUT constant to eliminate the warning from
i2c_set_timeout().

With these changes, the following results were obtained.  The I2C SCL
frequencies were measured with a Saleae logic analyzer.

ESP32 (TTGO T Dislay)
    I2C(0, scl=22, sda=21, freq=101781)  Measured: 100KHz
    I2C(0, scl=22, sda=21, freq=430107)  Measured: 400KHz
    I2C(0, scl=22, sda=21, freq=1212121) Measured: 941KHz

ESP32-S3 (TTGO T-QT)
    I2C(0, scl=34, sda=33, freq=111111)  Measured: 107KHz
    I2C(0, scl=34, sda=33, freq=444444)  Measured: 400KHz
    I2C(0, scl=34, sda=33, freq=1111111) Measured: 842KHz

ESP32-C3 (XIAO ESP32C3)
    I2C(0, scl=7, sda=6, freq=107816)  Measured: 103KHz
    I2C(0, scl=7, sda=6, freq=444444)  Measured: 380KHz
    I2C(0, scl=7, sda=6, freq=1176470) Measured: 800KHz

(ESP32-S2 board was not available for testing.)
2022-10-28 19:06:41 +11:00
Damien George
6643b4f0cc samd/machine_timer: Use extmod version of machine.Timer.
Signed-off-by: Damien George <damien@micropython.org>
2022-10-27 14:45:24 +11:00
Damien George
0159085666 renesas-ra/machine_timer: Use extmod version of machine.Timer.
Signed-off-by: Damien George <damien@micropython.org>
2022-10-27 14:44:12 +11:00
Damien George
98cbace299 mimxrt/machine_timer: Use extmod version of machine.Timer.
Signed-off-by: Damien George <damien@micropython.org>
2022-10-27 14:43:03 +11:00
Damien George
cd35b8a2a3 extmod/machine_timer: Move stm32's implementation of machine.Timer here.
So it can be reused by other ports.

Signed-off-by: Damien George <damien@micropython.org>
2022-10-27 14:32:43 +11:00
Damien George
e8f5cfe0e1 nrf: Rename MICROPY_PY_MACHINE_TIMER to MICROPY_PY_MACHINE_TIMER_NRF.
So that it doesn't clash with the extmod version.

Also make the default for this enabled, so that most boards do not need to
configure it.

Signed-off-by: Damien George <damien@micropython.org>
2022-10-27 14:30:58 +11:00
robert-hh
65fa7fd8bb mimxrt/machine_timer: Use soft-timer implementation for machine.Timer.
This releases the hardware timers for other tasks, which need a higher
resolution and faster response.  And it is less port-specific code.
2022-10-27 14:09:29 +11:00
robert-hh
9d2e179fa5 mimxrt: Fix CPU freeze when calling __WFE() in MICROPY_EVENT_POLL_HOOK.
This issue affected i.MX RT 1052, 1062 and 1064.  It seems to be addressed
by Errata ERR006223, which also mentions i.MX RT101x and 102x, but these
devices worked well even without the change.  As a side effect, the current
consumption at an idle REPL drops significantly with this fix.

Fixes issue #7235.
2022-10-27 14:06:12 +11:00
robert-hh
e20bb98392 mimxrt/machine_pin: Add the Pin.toggle() method.
For consistency with other ports, even if this method is undocumented at
the moment.
2022-10-27 14:05:33 +11:00
Damien George
c138e10fbb py/makeversionhdr: Fall back to py/mpconfig.h instead of docs/conf.py.
Commit 64af916c11 removed the version string
from docs/conf.py.  py/mpconfig.h is a better place to get the version
from, so use that (when there is no git repository).

Signed-off-by: Damien George <damien@micropython.org>
2022-10-27 13:00:48 +11:00
robert-hh
11910e2fa1 docs/samd: Add documentation for the samd port.
Includes a general overview, a quickref, pinout tables, and the beginnings
of a tutorial.
2022-10-26 23:39:35 +11:00
Jim Mussared
64af916c11 docs/templates/layout.html: Indicate latest vs release docs.
When looking at latest (the default for docs.micropython.org), make it
clear that this isn't the release version.
 - Changes the version in the top-left to "latest".
 - Adds a message to the top of each page to explain.

For future release versions, add a short message to link to the latest
version.

This work was funded through GitHub Sponsors.

Signed-off-by: Jim Mussared <jim.mussared@gmail.com>
2022-10-26 16:23:20 +11:00
Jim Mussared
d75c7e822c py/obj: Add comments explaining the slot index scheme.
Signed-off-by: Jim Mussared <jim.mussared@gmail.com>
2022-10-26 00:08:41 +11:00
robert-hh
fcccfc176b samd/modmachine: Add machine.softreset().
For consistency with other ports.
2022-10-25 23:49:52 +11:00
robert-hh
a1eebc507e samd/machine_spi: Register SerCom objects as root pointers.
Protect SerCom (UART, SPI, I2C) objects from getting freed by the GC when
they go out of scope without being deinitialized.  Otherwise the ISR of a
Sercom may access an invalid data structure.
2022-10-25 23:48:37 +11:00
robert-hh
d74215a313 samd/machine_spi: Implement spi.deinit() and simplify sercom_deinit_all.
The sercom_deinit_all() function does not need the object pointers.
2022-10-25 23:46:00 +11:00
robert-hh
9c2bc379f1 samd/machine_uart: Use a finaliser to tidy up UART on soft reset.
And use the common sercom_table, saving a few bytes of RAM.
2022-10-25 23:44:49 +11:00
robert-hh
474233c250 samd/machine_pwm: Serialize fast update of PWM settings.
Any update of freq or duty_cycle requires the previous PWM cycle to be
finished.  Otherwise the new settings are not accepted.

Other changes in this commit:
- Report the set duty cycles even when the PWM is not yet started.
- pwm.freq(0) stops the pwm device, instead of raising an expception.
- Clear the duty cycle value cache on soft reset.
2022-10-25 23:42:14 +11:00
robert-hh
ac1e31267b samd/boards: Rework the pins.csv files.
Changes are:
- Remove the LED_Pxxx definitions from pins.csv, now that the LED class is
  gone.
- Remove the '-' lines.
- Add default lines for USB and SWCLK, SWDIO.
2022-10-25 23:40:28 +11:00
robert-hh
a6760bd4ef samd/modmachine: Replace the LED class by the Signal class.
It simplifies and improves the code.  The LED_Pxxx lines of the board.csv
lines can still be used, but will be taken as Pin definitions.
2022-10-25 23:39:41 +11:00
robert-hh
4d38ab652e samd: Make ADC, DAC, PWM, SPI objects consistent in how they print out.
All of ADC, DAC, Pin, PWM and SPI looked different before this change.
2022-10-25 23:36:01 +11:00
robert-hh
e5cf3fab95 samd/machine_pin: Change the pin handling and naming/numbering.
Pin numbers are now the MCU port numbers in the range:

    PA0..PA31:  0..31
    PB0..PB31: 32..63
    PC0..PC31: 64..95
    PD0..PD31: 96..127

Pins can be denoted by the GPIO port number, the name as defined in
pins.csv or a string in the form Pxnn, like "PA16" or "PD03".

The pins.c and pins.h files are now obsolete.  The pin objects are part of
the AF table.

As result of a simplification, the code now supports using pin names or
numbers instead of pin objects for modules like UART, SPI, PWM, I2C, ADC,
pininfo.
2022-10-25 23:34:07 +11:00
robert-hh
e7aa9700ca samd/boards/SEEED_WIO_TERMINAL: Declare more pins for SEEED WIO board.
Defining all pins from the external 40 Pin connector, and some internal
pins like the one for SD and LCD.
2022-10-25 23:28:34 +11:00
robert-hh
e33db80a59 samd/clock_config: Extend the SAMD51 us-counter to 60 bit.
This removes the difference in the time.ticks_us() range between SAMD21 and
SAMD51.

The function mp_hal_ticks_us_64() is added and used for:
- SAMD51's mp_hal_ticks_us and mp_hal_delay_us().
  For SAMD21, keep the previous methods, which are faster.
- mp_hal_ticks_ms() and mp_hal_tick_ms_64(), which saves some bytes
  and removes a potential race condition every 50 days.

Also set the us-counter for SAMD51 to 16 MHz for a faster reading of the
microsecond value.

Note: With SAMD51, mp_hal_ticks_us_64() has a 60 bit range only, which is
still a long time (~36000 years).
2022-10-25 23:26:14 +11:00
robert-hh
fc9d66fac6 samd/machine_rtc: Add the machine.RTC class.
Methods implemented are:
- rtc.init(date)
- rtc.datetime([new_date])
- rtc.calibration(value)

The presence of this class can be controlled by MICROPY_PY_MACHINE_RTC.  If
the RTC module is used, the time module uses the RTC as well.

For boards without a 32kHz crystal, using RTC makes no sense, since it will
then use the ULP32K oscillator, which is not precise at all.  Therefore, it
will by default only be enabled for boards using a crystal, but can be
enabled in the respective mpconfigboard.h.
2022-10-25 23:20:09 +11:00
robert-hh
be31fde012 samd/mcu: Make some settings in mpconfigmcu.h conditional.
And set the default for MICROPY_PY_MATH as 1 for both MCU types.
2022-10-25 23:13:58 +11:00
robert-hh
2251cb774b samd/machine_uart: Implement uart.txdone() and uart.flush().
Using the stream method for uart.flush().

uart.txdone() returns True, if the uart not busy, False otherwise.

uart.flush() waits until all bytes have been transmitted or a timeout
triggers.  The timeout is determined by the buffer size and the baud rate.

Also fix two inconsistencies when not using txbuf:
- Report in ioctl as being writeable if there is room in the tx buffer,
  only if it is configured.
- Print the txbuf size if configured.
2022-10-25 23:11:57 +11:00
robert-hh
ddd41b8bbf samd/clock_config: Document the #defines use in init_clocks().
Which may be set in the respective mpconfigboard.h files.
2022-10-25 23:10:27 +11:00
robert-hh
f0399d35e4 samd/modmachine: Get the bootloader magic address from the lib.
Instead of being hard-coded, and then it works for all MCUs.

That fits except for a Sparkfun SAMD51 Thing Plus (known) bug, which uses
192k - 4 as magic address.  Therefore, that address is set as well to avoid
a problem when this bug is fixed by Sparkfun.
2022-10-25 23:09:04 +11:00
robert-hh
03075a6839 samd/modmachine: Implement machine.lightsleep().
Which just sets the CPU clock to 200kHz and switches the peripheral clock
off.  There are two modes:

    machine.lightsleep(duration_ms)

and

    machine.lightsleep()

In any mode any configured pin.irq() event will terminate the sleep.

Current consumption in lightsleep for some boards:
- 1.5 - 2.5 mA when supplied trough an active USB
  (Seeed XIAO w/o power LED, Adafruit ItsyBitsy)
- 0.8 - 2 mA when supplied through Gnd/+5V (Vusb)
  (Seeed XIAO w/o power LED, Adafruit ItsyBitsy)
- < 1 mA for SAMD51 when supplied trough a battery connector
  (Sparkfun Thing SAMD51 plus)

Related change: move the calls to SysTick_Config() into set_cpu_freq().  It
is required after each CPU freq change to have ticks_ms run at the proper
rate.
2022-10-25 23:07:27 +11:00
robert-hh
4c9e4c3310 samd/mcu/samd51: Enable FAT support for SAMD51.
Tested with a SD card connected to a SAMD51 board.  The SEEED WIO terminal
has a SD-Card reader built-in.

Also a side change to remove a few obsolete lines from Makefile.
2022-10-25 23:07:23 +11:00
robert-hh
fe31fca462 samd/mcu/samd51: Enable onewire support for SAMD51. 2022-10-25 23:07:01 +11:00
robert-hh
a7113e95d7 samd/modmachine: Add machine.dht_readinto and enable on SAMD51. 2022-10-25 23:06:44 +11:00
robert-hh
0d3f0d7470 samd/boards/SPARKFUN_SAMD51_THING_PLUS: Add board files for Thing Plus.
That device uses an SAMD51J20 MCU with 256k RAM and 1024k flash.
2022-10-25 22:42:17 +11:00
robert-hh
64e3c351de samd/modmachine: Add machine.reset_cause(). 2022-10-25 22:41:31 +11:00
robert-hh
1c32cec7f1 samd/clock_config: Support changing machine.freq() for SAMD21.
The range is 1MHz - 48 MHz.  Note that below 8 MHz there is no USB support.
The frequency will be set to an integer fraction of 48 MHz.  And after
changing the frequency, the peripherals like PWM, UART, I2C, SPI have to be
reconfigured.

Current consumption e.g. of the Seeed Xiao board at 1 MHz is about 1.5 mA,
mostly caused by the on-board LED (green LED with 1k resistor at 3.3V).
2022-10-25 22:40:16 +11:00
robert-hh
edc3f3d0d3 samd/clock_config: Extend the range of machine.freq().
The value given for machine.freq(f) is extend to the range of 1_000_000 to
200_000_000.  Frequencies below 48 MHz will be forced to an integer
fraction of 48 MHz.  At frequencies below 8 MHz USB is switched off.  The
power consumption e.g. of ADAFRUIT_ITSYBITSY_M4_EXPRESS drops to about
1.5 mA at 1 MHz.

Since the peripheral frequency is dropped as well, timing e.g. of PWM,
UART, I2C and SPI is affected and frequency/baud rate has to set again
after a frequency change below 48 MHz.
2022-10-25 22:38:45 +11:00
Jim Mussared
1ba0e8ff96 py/persistentcode: Only emit sub-version if generated code has native.
In order for v1.19.1 to load a .mpy, the formerly-feature-flags which are
now used for the sub-version must be zero.

The sub-version is only used to indicate a native version change, so it
should be zero when emitting bytecode-only .mpy files.

This work was funded through GitHub Sponsors.

Signed-off-by: Jim Mussared <jim.mussared@gmail.com>
2022-10-25 14:57:04 +11:00
Jim Mussared
5ee1cb2771 stm32/boards/ARDUINO_PORTENTA_H7: Revert to single-precision float.
Using repr C is incompatible with double-precision floats on 32-bit arch.

Signed-off-by: Jim Mussared <jim.mussared@gmail.com>
2022-10-25 14:46:04 +11:00