SysTick cannot wake the CPU from WFI/WFE so a hardware timer is needed to
keep track of ticks/delay (similar to the nrf port).
Fixes issue #7234.
Signed-off-by: Damien George <damien@micropython.org>
This detects an overflowed flash partition, such as
```
1452105 bytes used, -10313 bytes free in flash firmware space out of 1441792 bytes (1408.0kB).
444428 bytes used, 1652724 bytes free in ram for stack and heap out of 2097152 bytes (2048.0kB).
```
on a metro esp32-s2 built with debugging.
This also removes the need to pin share because we don't use the
status LED while user code is running.
The status flashes fallback to the HW_STATUS LED if no RGB LED is
present. Each status has a unique blink pattern as well.
One caveat is the REPL state. In order to not pin share, we set the
RGB color once. PWM and single color will be shutoff immediately but
DotStars and NeoPixels will hold the color until the user overrides
it.
Fixes#4133
A board can now customise mboot with:
- MBOOT_LED1, MBOOT_LED2, MBOOT_LED3, MBOOT_LED4: if it needs to have
different LEDs for mboot compared to the application
- MBOOT_BOARD_LED_INIT: if it needs a fully customised LED init function
- MBOOT_BOARD_LED_STATE: if it needs a fully customised LED state-setting
function
- MBOOT_BOARD_GET_RESET_MODE: if it needs a fully customised function to
get the reset mode
With full customisation, the only requirement is a single LED to show the
status of the bootloader (idle, erasing, flashing, etc), which can be
configured to do nothing if needed.
Signed-off-by: Damien George <damien@micropython.org>
It is enabled by default to get the standard behaviour of doing a reset
after it is finished, but can be disabled by a board to jump straight to
the application (likely the board needs to use MBOOT_BOARD_CLEANUP to make
this work).
The application is passed a reset mode of BOARDCTRL_RESET_MODE_BOOTLOADER
if the bootloader was active and entered via a jump.
Signed-off-by: Damien George <damien@micropython.org>
This new logic is equivalent to the old logic when the only possibilities
for reset_mode are NORMAL, SAFE_MODE and FILESYSTEM, which is the standard
case. But the new logic also allows other reset_mode values (eg
BOOTLOADER) to run boot.py and main.py.
Signed-off-by: Damien George <damien@micropython.org>
When disabled the bootloader is entered via a direct jump. When enabled
the bootloader is entered via a system reset then a jump. It's enabled by
default to retain the existing behaviour, which is the recommended way.
Signed-off-by: Damien George <damien@micropython.org>