In order to have more fine-grained control over how builtin functions are
constructed, the MP_DECLARE_CONST_FUN_OBJ macros are made more specific,
with suffix of _0, _1, _2, _3, _VAR, _VAR_BETEEN or _KW. These names now
match the MP_DEFINE_CONST_FUN_OBJ macros.
Converts generted pins to use qstrs instead of string pointers.
This patch also adds the following functions:
pyb.Pin.names()
pyb.Pin.af_list()
pyb.Pin.gpio()
dir(pyb.Pin.board) and dir(pyb.Pin.cpu) also produce useful results.
pyb.Pin now takes kw args.
pyb.Pin.__str__ now prints more useful information about the pin
configuration.
I found the following functions in my boot.py to be useful:
```python
def pins():
for pin_name in dir(pyb.Pin.board):
pin = pyb.Pin(pin_name)
print('{:10s} {:s}'.format(pin_name, str(pin)))
def af():
for pin_name in dir(pyb.Pin.board):
pin = pyb.Pin(pin_name)
print('{:10s} {:s}'.format(pin_name, str(pin.af_list())))
```
Make a clearer distinction between init functions that must be done
before any scripts can run (xxx_init0) and those that can be safely
deferred (xxx_init).
Fix bug initialising USB VCP exception. Addresses issue #788.
Re-order some init function to improve reliability of
reset/soft-reset.
Conflicts:
stmhal/pin_named_pins.c
stmhal/readline.c
Renamed HAL_H to MICROPY_HAL_H. Made stmhal/mphal.h which intends to
define the generic Micro Python HAL, which in stmhal sits above the ST
HAL.
Blanket wide to all .c and .h files. Some files originating from ST are
difficult to deal with (license wise) so it was left out of those.
Also merged modpyb.h, modos.h, modstm.h and modtime.h in stmhal/.
This is an attempt to clean up the Micro Python API on the pyboard.
Gpio functionality is now in the Pin object, which seems more natural.
Constants for MODE and PULL are now in pyb.Pin. Names of some
classes have been adjusted to conform to CamelCase. Other
miscellaneous changes and clean up here and there.
Added support for the ADC channels and mappings to make_pins.py
I'm not sure if the hal properly deals with the channel 16/18 differences
between the 40x and 42x. It seems to deal with it partially. This particular
aspect will need testing on a 42x or 43x.