This allows the application to be notified of changes to the connection
interval, connection latency and supervision timeout.
Signed-off-by: Jim Mussared <jim.mussared@gmail.com>
This commit switches the roles of the helper task from a cancellation task
to a runner task, to get the correct semantics for cancellation of
wait_for.
Some uasyncio tests are now disabled for the native emitter due to issues
with native code generation of generators and yield-from.
Fixes#5797.
Signed-off-by: Damien George <damien@micropython.org>
This is added because task.coro==None is no longer the way to detect if a
task is finished. Providing a (CPython compatible) function for this
allows the implementation to be abstracted away.
Signed-off-by: Damien George <damien@micropython.org>
When a tasks raises an exception which is uncaught, and no other task
await's on that task, then an error message is printed (or a user function
called) via a call to Loop.call_exception_handler. In CPython this call is
made when the Task object is freed (eg via reference counting) because it's
at that point that it is known that the exception that was raised will
never be handled.
MicroPython does not have reference counting and the current behaviour is
to deal with uncaught exceptions as early as possible, ie as soon as they
terminate the task. But this can be undesirable because in certain cases
a task can start and raise an exception immediately (before any await is
executed in that task's coro) and before any other task gets a chance to
await on it to catch the exception.
This commit changes the behaviour so that tasks which end due to an
uncaught exception are scheduled one more time for execution, and if they
are not await'ed on by the next scheduling loop, then the exception handler
is called (eg the exception is printed out).
Signed-off-by: Damien George <damien@micropython.org>
Also known as L2CAP "connection oriented channels". This provides a
socket-like data transfer mechanism for BLE.
Currently only implemented for NimBLE on STM32 / Unix.
Signed-off-by: Jim Mussared <jim.mussared@gmail.com>
Hardware I2C implementations must provide a .init() protocol method if they
want to support reconfiguration. Otherwise the default is that i2c.init()
raises an OSError (currently the case for all ports).
mp_machine_soft_i2c_locals_dict is renamed to mp_machine_i2c_locals_dict to
match the generic SPI bindings.
Fixes issue #6623 (where calling .init() on a HW I2C would crash).
Signed-off-by: Damien George <damien@micropython.org>
This changes stm32 from using PENDSV to run NimBLE to use the MicroPython
scheduler instead. This allows Python BLE callbacks to be invoked directly
(and therefore synchronously) rather than via the ringbuffer.
The NimBLE UART HCI and event processing now happens in a scheduled task
every 128ms. When RX IRQ idle events arrive, it will also schedule this
task to improve latency.
There is a similar change for the unix port where the background thread now
queues the scheduled task.
Signed-off-by: Jim Mussared <jim.mussared@gmail.com>
This requires that the event handlers are called from non-interrupt context
(i.e. the MicroPython scheduler).
This will allow the BLE stack (e.g. NimBLE) to run from the scheduler
rather than an IRQ like PENDSV, and therefore be able to invoke Python
callbacks directly/synchronously. This allows writing Python BLE handlers
for events that require immediate response such as _IRQ_READ_REQUEST (which
was previous a hard IRQ) and future events relating to pairing/bonding.
Signed-off-by: Jim Mussared <jim.mussared@gmail.com>
Using a semaphore (the previous approach) will only run the UART, whereas
for startup we need to also run the event queue.
This change makes it run the full scheduler hook.
Signed-off-by: Jim Mussared <jim.mussared@gmail.com>
Instead of having the stack indicate a "start", "data"..., "end", pass
through the data in one callback as an array of chunks of data.
This is because the upcoming non-ringbuffer modbluetooth implementation
cannot buffer the data in the ringbuffer and requires instead a single
callback with all the data, to pass to the Python callback.
Signed-off-by: Jim Mussared <jim.mussared@gmail.com>
Prior to this change machine.mem32['foo'] (or using any other non-integer
subscript) could result in a fault due to 'foo' being interpreted as an
integer. And when writing code it's hard to tell if the fault is due to a
bad subscript type, or an integer subscript that specifies an invalid
memory address.
The type of the object used in the subscript is now tested to be an
integer by using mp_obj_get_int_truncated instead of
mp_obj_int_get_truncated. The performance hit of this change is minimal,
and machine.memX objects are more for convenience than performance (there
are many other ways to read/write memory in a faster way),
Fixes issue #6588.
If a port provides MICROPY_PY_URANDOM_SEED_INIT_FUNC as a source of
randomness then this will be used when urandom.seed() is called without
an argument (or with None as the argument) to seed the pRNG.
Other related changes in this commit:
- mod_urandom___init__ is changed to call seed() without arguments, instead
of explicitly passing in the result of MICROPY_PY_URANDOM_SEED_INIT_FUNC.
- mod_urandom___init__ will only ever seed the pRNG once (before it could
seed it again if imported by, eg, random and then urandom).
- The Yasmarang state is moved to the BSS for builds where the state is
guaranteed to be initialised on import of the (u)random module.
Signed-off-by: Damien George <damien@micropython.org>
Newer GCC versions are able to warn about switch cases that fall
through. This is usually a sign of a forgotten break statement, but in
the few cases where a fall through is intended we annotate it with this
macro to avoid the warning.
When compiling with -Wextra which includes -Wmissing-field-initializers
GCC will warn that the defval field of mp_arg_val_t is not initialized.
This is just a warning as it is defined to be zero initialized, but since
it is a union it makes sense to be explicit about which member we're
going to use, so add the explicit initializers and get rid of the
warning.
It requires mp_hal_time_ns() to be provided by a port. This function
allows very accurate absolute timestamps.
Enabled on unix, windows, stm32, esp8266 and esp32.
Signed-off-by: Damien George <damien@micropython.org>
With a warning that this way of constructing software I2C/SPI is
deprecated. The check and warning will be removed in a future release.
This should help existing code to migrate to the new SoftI2C/SoftSPI types.
Signed-off-by: Damien George <damien@micropython.org>
The SoftSPI constructor is now used soley to create SoftSPI instances, it
can no longer delegate to create a hardware-based SPI instance.
Signed-off-by: Damien George <damien@micropython.org>
The SoftI2C constructor is now used soley to create SoftI2C instances, it
can no longer delegate to create a hardware-based I2C instance.
Signed-off-by: Damien George <damien@micropython.org>
Also rename machine_i2c_type to mp_machine_soft_i2c_type. These changes
make it clear that it's a soft-I2C implementation, and match SoftSPI.
Signed-off-by: Damien George <damien@micropython.org>
A read-only memoryview object is a better representation of the data, which
is owned by the ubluetooth module and may change between calls to the
user's irq callback function.
Signed-off-by: Damien George <damien@micropython.org>
Prior to this commit, uos.chdir('/') followed by uos.stat('noexist') would
succeed that stat even though the entry did not exist (some other functions
like listdir would have similar issues). This is because, if the current
directory was the root and the path was relative, mp_vfs_lookup_path would
return success for bad paths.
Signed-off-by: Damien George <damien@micropython.org>
For time-based functions that work with absolute time there is the need for
an Epoch, to set the zero-point at which the absolute time starts counting.
Such functions include time.time() and filesystem stat return values. And
different ports may use a different Epoch.
To make it clearer what functions use the Epoch (whatever it may be), and
make the ports more consistent with their use of the Epoch, this commit
renames all Epoch related functions to include the word "epoch" in their
name (and remove references to "2000").
Along with this rename, the following things have changed:
- mp_hal_time_ns() is now specified to return the number of nanoseconds
since the Epoch, rather than since 1970 (but since this is an internal
function it doesn't change anything for the user).
- littlefs timestamps on the esp8266 have been fixed (they were previously
off by 30 years in nanoseconds).
Otherwise, there is no functional change made by this commit.
Signed-off-by: Damien George <damien@micropython.org>
For the following 3 functions, previously the code relied on whether the
arg was passed at all, to make it optional. Now it allows them to be
explicitly `None` to indicate they are not used:
- gatts_notify(..., [data])
- gattc_discover_services(..., [uuid])
- gattc_discover_characteristics(..., [uuid])
Also ensure that the uuid arguments are actually instances of the uuid
type, and fix handling of the 5th arg in gattc_discover_characteristics().
This allows `ble.active(1)` to fail correctly if the HCI controller is
unavailable.
It also avoids an infine loop in the NimBLE event handler where NimBLE
doesn't correctly detect that the HCI controller is unavailable and keeps
trying to reset.
Furthermore, it fixes an issue where GATT service registrations were left
allocated, which led to a bad realloc if the stack was activated multiple
times.
Generally a controller should either have its own public address hardcoded,
or loaded by the driver (e.g. cywbt43).
However, for a controller that has no public address where you still want a
long-term stable address, this allows you to use a static address generated
by the port. Typically on STM32 this will be an LAA, but a board might
override this.
This commit adds support for using Bluetooth on the unix port via a H4
serial interface (distinct from a USB dongle), with both BTstack and NimBLE
Bluetooth stacks.
Note that MICROPY_PY_BLUETOOTH is now disabled for the coverage variant.
Prior to this commit Bluetooth was anyway not being built on Travis because
libusb was not detected. But now that bluetooth works in H4 mode it will
be built, and will lead to a large decrease in coverage because Bluetooth
tests cannot be run on Travis.
Previously the interaction between the different layers of the Bluetooth
stack was different on each port and each stack. This commit defines
common interfaces between them and implements them for cyw43, btstack,
nimble, stm32, unix.
This is consistent with the other 'micro' modules and allows implementing
additional features in Python via e.g. micropython-lib's sys.
Note this is a breaking change (not backwards compatible) for ports which
do not enable weak links, as "import sys" must now be replaced with
"import usys".
By setting MICROPY_EPOCH_IS_1970 a port can opt to use 1970/1/1 as the
Epoch for timestamps returned by stat(). And this setting is enabled on
the unix and windows ports because that's what they use.
Signed-off-by: Damien George <damien@micropython.org>
On ports like unix where the Epoch is 1970/1/1 and atime/mtime/ctime are in
seconds since the Epoch, this value will overflow a small-int on 32-bit
systems. So far this is only an issue on 32-bit unix builds that use the
VFS layer (eg dev and coverage unix variants) but the fix (using
mp_obj_new_int_from_uint instead of MP_OBJ_NEW_SMALL_INT) is there for all
ports so as to not complicate the code, and because they will need the
range one day.
Also apply a similar fix to other fields in VfsPosix.stat because they may
also be large.
Signed-off-by: Damien George <damien@micropython.org>