Commit Graph

11 Commits

Author SHA1 Message Date
iabdalkader
e275a58ac1 samd: Rename machine I2C type consistently across ports.
This renames:
- machine_hw_i2c_type -> machine_i2c_type
2022-10-22 12:57:32 +11:00
robert-hh
f5da77b5ce samd/machine_dac: Add the machine.DAC class.
It suuports 1 channel @ 10 bit for SAMD21, 2 channels @ 12 bit for SAMD51.

Instantiation by:

    dac = machine.DAC(ch) # 0 or 1

Method write:

    dac.write(value)

The output voltage range is 0..Vdd.
2022-10-06 22:55:10 +11:00
robert-hh
7a2f2d88f7 samd/machine_wdt: Add the machine.WDT class. 2022-10-06 22:53:06 +11:00
robert-hh
32c973d554 samd/machine_timer: Add machine.Timer based on the shared soft-timer. 2022-10-06 22:52:39 +11:00
robert-hh
94d27ae28f samd/machine_i2c: Add the machine.I2C class.
Using the common API.  Tested with SAMD21 and SAMD51 boards.
2022-10-06 22:49:06 +11:00
robert-hh
aa870708ac samd/machine_spi: Add the machine.SPI class.
Suported by both SAMD21 and SAMD51.  It follows the generic API, except for
the bits=nn option, which is not implemented (yet).
2022-10-06 22:48:44 +11:00
robert-hh
b33f204529 samd/machine_uart: Add the machine.UART class.
All board pins that have UART's assigned can be used.  Baud rate range is
75 Baud to ~2 MBaud.

No flow control yet, and only RX is buffered.  TX buffer and flow control
may be added later for SAMD51 with its larger RAM and Flash.
2022-10-06 22:48:12 +11:00
robert-hh
d693758ab2 samd/machine_pwm: Add the machine.PWM class.
Features are:
- 3 to 5 different frequency groups.
- Freq range of 1Hz - 24 MHz.
- Duty rate stays stable on freq change.

Keyword options to the PWM constructor:
- device=n Select a specific PWM device.  If no device is specified, a free
           device is chosen, if available at that pin.
- freq=nnnn
- duty_u16=nnnn
- duty_ns=nnnn
- invert=True/False Allowing two outputs on the same device/channel to have
                    complementary signals.

If both freq and duty are provided, PWM output will start immediately.

Pins at the same device have the same frequency.  If the PWM output number
exceeds the number of channels at the PWM device, the effctive channel_no
is output_no % channel_count.  So with a channel count of 4, output 7 is
assigned to channel 3.  Pins at a certain channel have the same frequency
and duty rate, but may be seperately inverted.
2022-10-06 22:42:55 +11:00
robert-hh
5c7e93ec48 samd/machine_adc: Add the machine.ADC class.
With the method read_u16().  Keyword arguments of the constructor are:
- bits=n    The resolution; default is 12.
- average=n The average of samples, which are taken and cumulated.  The
            default value is 16.  Averaging by hw is faster than averaging
            in code.

The ADC runs at a clock freq 1.5 MHz.  A single 12 bit conversion takes
8 microseconds.
2022-10-06 22:41:44 +11:00
robert-hh
85afed569d samd: Remove the existing provisional support for REPL on UART.
It was only partially working and will be rpelaced later by a full
machine.UART class implementation.
2022-10-06 22:29:06 +11:00
Peter van der Burg
2f65ded1a2 samd: Add Pin and LED classes, and machine.unique_id. 2021-11-19 11:43:06 +11:00