Instead of being an explicit field, it's now a slot like all the other
methods.
This is a marginal code size improvement because most types have a make_new
(100/138 on PYBV11), however it improves consistency in how types are
declared, removing the special case for make_new.
Signed-off-by: Jim Mussared <jim.mussared@gmail.com>
Just another choice for the PHY interface.
Added: Keyword option phy_clock=LAN.IN or LAN.OUT
to define the source of the 50MHZ clock for the PHY
interface. The RMII clock is not enabled if it
is generated by a PYH board. Constants:
LAN.IN The clock is provided by the PHY board.
LAN.OUT The clock is provided by the MCU board.
The default is LAN.OUT or the value set in mpconfigboard.h, which
is currently set to IN only for the SEEED ARCH MIX board. Usage etc:
lan = LAN(phy_type=LAN.PHY_DP83848, phy_clock=LAN.IN)
Useful for boards without a PHY interface, where that has to be
attached. Like the Seed ARCH MIX board or Vision SOM. Phy drivers
supported so far are:
- KSZ8081
- DP83825
- LAN8720
More to come. Usage e.g.:
lan = LAN(phy_type=LAN.PHY_LAN8720, phy_addr=1)
The default values are those set in mpconfigboard.h.
This commit implements 10/100 Mbit Ethernet support in the mimxrt port.
The following boards are configured without ETH network:
- MIMXRT1010_EVK
- Teensy 4.0
The following boards are configured with ETH network:
- MIMXRT1020_EVK
- MIMXRT1050_EVK
- MIMXRT1060_EVK
- MIMXRT1064_EVK
- Teensy 4.1
Ethernet support tested with TEENSY 4.1, MIMRTX1020_EVK and MIMXRT1050_EVK.
Build tested with Teensy 4.0 and MIMXRT1010_EVK to be still working.
Compiles and builds properly for MIMXRT1060_EVK and MIMXRT1064_EVK, but not
tested lacking suitable boards.
Tested functions are:
- ping works bothway
- simple UDP transfer works bothway
- ntptime works
- the ftp server works
- secure socker works
- telnet and webrepl works
The MAC address is 0x02 plus 5 bytes from the manifacturing info field,
which can be considered as unique per device.
Some boards do not wire the RESET and INT pin of the PHY transceiver. For
operation, these are not required. If they are defined, they will be used.