2.5 can be represented correctly in object representation C, but 2.3 cannot
(it is slightly truncated).
Signed-off-by: Damien George <damien@micropython.org>
Commit 0abf6f830c removed _boot.py from the
manifest for the GENERIC_512K board because the build does not include a
filesystem. But the main code expects _boot.py to be there and prints an
error if it's not. So add a custom _boot.py, which just sets the
gc.threshold().
Signed-off-by: Damien George <damien@micropython.org>
The 72x40 OLED requires selecting the internal IREF, as opposed to the
default external IREF. This is an undocumented feature in the SSD1306
datasheet, but is present in the SSD1315 datasheet. It's possible the
72x40 OLED is actually using the newer SSD1315 controller. Sending the
IREF select command to SSD1306 displays has no effect on them, so it's
added to the init_display() instead of wrapping in an "if width = 72".
Also tested on a 128x64 OLED using the SSD1315 controller (smaller ribbon
cable) and the proposed change has no effect on the display, as the module
comes with the correct current limiting resistor. Internal and external
IREF work the same.
Fixes issue #7281.
This adds a wlan.config(reconnects=N) option to set the number of reconnect
attempts that will be made if the WLAN connection goes down. The default
is N=-1 (infinite retries, current behavior). Setting
wlan.config(reconnects=0) will disable the reconnect attempts.
A nice side effect of reconnects=0 is that wlan.status() will report the
disconnect reason now. See related issue #5326.
Ethernet-PHYs from ESP-IDF (LAN8720, IP101, RTL8201, DP83848) are now
supported in IDF v4.1 and above. PHY_KSZ8041 is only for ESP-IDF 4.3 and
above. ESP32S2 is not supported.
Signed-off-by: Tobias Eydam <eydam-prototyping@outlook.com>
The comments in NimBLE for ble_gattc_notify_custom() state that "This
function consumes the supplied mbuf regardless of the outcome.". And
inspection of NimBLE code shows that this is the case. So the comment can
be removed.
Signed-off-by: Damien George <damien@micropython.org>
This commit fixes a problem with a race between cancellation of task A and
completion of task B, when A waits on B. If task B completes just before
task A is cancelled then the cancellation of A does not work. Instead,
the CancelledError meant to cancel A gets passed through to B (that's
expected behaviour) but B handles it as a "Task exception wasn't retrieved"
scenario, printing out such a message (this is because finished tasks point
their "coro" attribute to themselves to indicate they are done, and
implement the throw() method, but that method inadvertently catches the
CancelledError). The correct behaviour is for B to bounce that
CancelledError back out.
This bug is mainly seen when wait_for() is used, and in that context the
symptoms are:
- occurs when using wait_for(T, S), if the task T being waited on finishes
at exactly the same time as the wait-for timeout S expires
- task T will have run to completion
- the "Task exception wasn't retrieved message" is printed with
"<class 'CancelledError'>" as the error (ie no traceback)
- the wait_for(T, S) call never returns (it's never put back on the
uasyncio run queue) and all tasks waiting on this are blocked forever
from running
- uasyncio otherwise continues to function and other tasks continue to be
scheduled as normal
The fix here reworks the "waiting" attribute of Task to be called "state"
and uses it to indicate whether a task is: running and not awaited on,
running and awaited on, finished and not awaited on, or finished and
awaited on. This means the task does not need to point "coro" to itself to
indicate finished, and also allows removal of the throw() method.
A benefit of this is that "Task exception wasn't retrieved" messages can go
back to being able to print the name of the coroutine function.
Fixes issue #7386.
Signed-off-by: Damien George <damien@micropython.org>
The implementation uses the LPUARTx devices. Up to 8 UARTs can be used,
given that the pins are accessible. E.g. 8 on Teensy 4.1, 5 on
MIMXRT1020_EVK.
For Tennsy 4.0 and 4.1 the UART numbers are as printed on the pinout 1..N.
The MIMXRT10xx-EVK boards have only one UART named, which gets the number
1. All other UART are assigned to different Pins:
MIMXRT1010-EVK:
D0/D1 UART 1
D6/D7 UART 2
A0/D4 UART 3
MIMXRT1020-EVK:
D0/D1 UART 1
D6/D9 UART 2
D10/D12 UART 3
D14/D15 UART 4
A0/A1 UART 5
MIMXRT1050-EVK, MIMXRT1060-EVK, MIMXRT1064-EVK:
D0/D1 UART 1
D7/D6 UART 2
D8/D9 UART 3
A1/A0 UART 4
Now a ctrl-C will not stop mpremote, rather this character will be passed
through to the attached device.
The mpremote version is also increased to 0.0.5.
Signed-off-by: Damien George <damien@micropython.org>
Using just the list of available ports, instead of a hard-coded list of
possible ports, means that all ports will be available for auto connection.
And the order that they will be attempted in will match what's printed by
"mpremote connect list" (and will be the same as before, trying ACMx before
USBx). Auto-connect will also now work on Mac, and will allow all COM
ports on Windows.
Signed-off-by: Damien George <damien@micropython.org>
With docs and a multi-test using TCP server/client.
This method is a MicroPython extension, although there is discussion of
adding it to CPython: https://bugs.python.org/issue41305
Signed-off-by: Mike Teachman <mike.teachman@gmail.com>
This fixes error: cast to smaller integer type 'int' from 'pthread_t'.
pthread_t is defined as long, not as int.
Signed-off-by: Pavol Rusnak <pavol@rusnak.io>
The rtc_set_datetime() from pico-sdk will validate the values in the
datetime_t structure and refuse to set the time if they aren't valid. It
makes sense to raise an exception if this happens instead of failing
silently which might be confusing (as an example, see:
https://github.com/micropython/micropython/pull/6928#issuecomment-860166044
).