To reset the flags we should write to the single bit only, not the entire
register (otherwise all other settings in the register are cleared).
Fixes#2457.
Having a micropython.const identity function, and writing "from micropython
import const" at the start of scripts that use the const feature, allows to
write scripts which are compatible with CPython, and with uPy builds that
don't include const optimisation.
This patch adds such a function and updates the tests to do the import.
When an exception is raised and is to be handled by the VM, it is stored
on the Python value stack so the bytecode can access it. CPython stores
3 objects on the stack for each exception: exc type, exc instance and
traceback. uPy followed this approach, but it turns out not to be
necessary. Instead, it is enough to store just the exception instance on
the Python value stack. The only place where the 3 values are needed
explicitly is for the __exit__ handler of a with-statement context, but
for these cases the 3 values can be extracted from the single exception
instance.
This patch removes the need to store 3 values on the stack, and instead
just stores the exception instance.
Code size is reduced by about 50-100 bytes, the compiler and VM are
slightly simpler, generate bytecode is smaller (by 2 bytes for each try
block), and the Python value stack is reduced in size for functions that
handle exceptions.
This fixes constant substitution so that only standalone identifiers are
replaced with their constant value (if they have one). I.e. don't
replace NAME in expressions like obj.NAME or NAME = expr.
qstrs ids are restricted to fit within 2 bytes already (eg in persistent
bytecode) so it's safe to use a uint16_t to store them in mp_arg_t. And
the flags member only needs a maximum of 2 bytes so can also use uint16_t.
Savings in code size can be significant when many mp_arg_t structs are
used for argument parsing. Eg, this patch reduces stmhal by 480 bytes.
When the clock is too fast for the i2c slave, it can temporarily hold
down the scl line to signal to the master that it needs to wait. The
master should check the scl line when it is releasing it after
transmitting data, and wait for it to be released.
This change has been tested with a logic analyzer and an i2c slace
implemented on an atmega328p using its twi peripheral, clocked at 8Mhz.
Without the change, the i2c communication works up to aboy 150kHz
frequency, and above that results in the slave stuck in an unresponsive
state. With this change, communication has been tested to work up to
400kHz.
The system printf is no longer used by the core uPy code. Instead, the
platform print stream or DEBUG_printf is used. Using DEBUG_printf in the
showbc functions would mean that the code can't be tested by the test
suite, so use the normal output instead.
This patch also fixes parsing of bytecode-line-number mappings.