Preserve ticks for displays across VMs
This commit is contained in:
parent
862188d2ee
commit
b25d810af9
@ -131,7 +131,11 @@
|
||||
static volatile bool sleep_ok = true;
|
||||
|
||||
#ifdef SAMD21
|
||||
uint8_t _tick_event_channel;
|
||||
static uint8_t _tick_event_channel = EVSYS_SYNCH_NUM;
|
||||
|
||||
static bool tick_enabled(void) {
|
||||
return _tick_event_channel != EVSYS_SYNCH_NUM;
|
||||
}
|
||||
|
||||
// Sleeping requires a register write that can stall interrupt handling. Turning
|
||||
// off sleeps allows for more accurate interrupt timing. (Python still thinks
|
||||
@ -431,8 +435,15 @@ void reset_port(void) {
|
||||
pew_reset();
|
||||
#endif
|
||||
|
||||
#ifdef SAMD21
|
||||
if (!tick_enabled())
|
||||
// SAMD21 ticks depend on the event system, so don't disturb the event system if we need ticks,
|
||||
// such as for a display that lives across VM instantiations.
|
||||
#endif
|
||||
{
|
||||
reset_event_system();
|
||||
reset_ticks();
|
||||
}
|
||||
|
||||
reset_all_pins();
|
||||
|
||||
@ -613,8 +624,8 @@ void port_enable_tick(void) {
|
||||
RTC->MODE0.INTENSET.reg = RTC_MODE0_INTENSET_PER2;
|
||||
#endif
|
||||
#ifdef SAMD21
|
||||
// SAMD21 ticks won't survive reset_port(). This *should* be ok since it'll
|
||||
// be triggered by ticks and no Python will be running.
|
||||
// reset_port() preserves the event system if ticks were still enabled after a VM finished,
|
||||
// such as for an on-board display. Normally the event system would be reset between VM instantiations.
|
||||
if (_tick_event_channel >= EVSYS_SYNCH_NUM) {
|
||||
turn_on_event_system();
|
||||
_tick_event_channel = find_sync_event_channel();
|
||||
|
Loading…